A Detector System for Protonradiography — •M. Dellert1,2, J. Besserer1, J. de Boer1, C. Gahn1, G. Graw1, M. Moosburger1, E. Pedroni2, P. Pemler3, and U. Schneider31Sektion Physik, Ludwig-Maximilians-Universität München, 85748 Garching, Germany — 2Paul Scherrer Institut, 5232 Villigen, Switzerland — 3Stadtspital Triemli, 8063 Zürich, Switzerland

For the gantry of the proton irradiation facility at the Paul–Scherrer–Institute a detector system for fast in–vivo protonradiography was developped and installed. The system will be used for quality assurance of the tumor therapy with protons but also as diagnostic tool with good density resolution and with low doses to the patient.
For each proton the entrance and exit coordinates are measured in coincidence with the residual range. Scintillating fiber hodoscopes are used as position–sensitive detectors, while the range of the protons is measured by a stack of scintillator plates. A fast front–end electronics and data–acquisition system can register protons at a rate up to one million events per second.
Radiographs of phantoms show the expected spatial and density resolution. The possibility for detecting inhomogeneities in the target volume is discussed.