DPG Phi
Verhandlungen
Verhandlungen
DPG

Erlangen 2018 – wissenschaftliches Programm

Bereiche | Tage | Auswahl | Suche | Aktualisierungen | Downloads | Hilfe

MS: Fachverband Massenspektrometrie

MS 1: Precision Mass Spectrometry 1

MS 1.3: Vortrag

Montag, 5. März 2018, 11:15–11:30, R 1.020

Precision Measurements of Neon Isotopes at THe-Trap — •Tom Segal, Martin Höcker, Jochen Ketter, Marc Schuh, Sebastian Streubel, and Klaus Blaum — Max-Planck-Institut für Kernphysik

THe-Trap is a precision Penning-trap mass spectrometer [1] at the Max-Planck-Institut für Kernphysik (MPIK) in Heidelberg. It aims to solve the 4-σ discrepancy in the mass measurements of helium-3 [2,3] by measuring its mass with a relative uncertainty of about 10−10. Left unresolved, the discrepancy increases the uncertainties of the hydrogen and deuterium masses, as well as the values of physical constants such as h, kB and NA. A new gas injection system was developed in preparation for the helium measurement. To test it, neon gas was successfully injected into the traps region and ionized by a field emission point. The produced ions were trapped and their cyclotron frequency measured. The measurement process will be presented, as well as preliminary mass results for 20Ne, 22Ne and future plans.

[1] S. Streubel et al., Applied Physics B: Lasers and Optics (2014), 114(1-2), 137-145

[2] R.S. Van Dyck et al., Metrologia (2015), Volume 52, Number 2

[3] E.G. Meyers et al., Phys. Rev. Lett (2015), 144,013003

100% | Mobil-Ansicht | English Version | Kontakt/Impressum/Datenschutz
DPG-Physik > DPG-Verhandlungen > 2018 > Erlangen