SMuK 2023 – wissenschaftliches Programm
Bereiche | Tage | Auswahl | Suche | Aktualisierungen | Downloads | Hilfe
HK: Fachverband Physik der Hadronen und Kerne
HK 13: Instrumentation IV
HK 13.4: Vortrag
Dienstag, 21. März 2023, 17:45–18:00, SCH/A251
Calibration of Detector Modules for the PANDA FAIR Phase-0 Calorimeter — Nicolo Baldicchi1, Luigi Capozza1, •Samet Katilmis1, Dong Liu1, Frank Maas1,2,3, Julian Moik1, Oliver Noll1,2, David Rodriguez Piñeiro1, Paul Schöner1, Christoph Rosner1, and Sahra Wolff1 — 1Helmholtz-Institut Mainz, Mainz, Germany — 2Institute of Nuclear Physics, Mainz, Germany — 3PRISMA+ Cluster of Excellence, Mainz, Germany
The PANDA FAIR Phase-0 Calorimiter consists of 48 submodules. Each submodule houses detector components, such as high voltage distribution boards, charge sensitive preamplifiers, avalanche photo diodes (APDs) and temperature sensors. The characteristics of these components must be determined to run the calorimeter in an optimal operating mode. Following parameters were determined and optimised. The APD gain as a function of the bias voltage at -25 ∘C, the entrance area of the PANDA charge sensitive preamplifier and the characteristic curves of both the HV boards and the platinum temperature sensors. Furthermore a first energy calibration of the submodules by utilising atmospheric muons was performed. The talk points out both technical developments and results.