Q 34.1: Vortrag

Donnerstag, 20. März 2014, 10:30–10:45, BEBEL SR140/142

Highly-sensitive image-current detection systems for BASE — •Christian Smorra1, Kurt Alan Franke1,2, Andreas Mooser3, Hiroki Nagahama1,4, Georg Ludwig Schneider1,3, Klaus Blaum2, Yasuyuki Matsuda4, Christian Ospelkaus5, Wolfgang Quint6, Jochen Walz3, Yasunori Yamazaki7, and Stefan Ulmer11RIKEN, Ulmer IRU, Japan — 2MPI-K Heidelberg, Germany — 3University of Mainz, Germany — 4Tokyo University, Japan — 5University of Hannover, Germany — 6GSI Darmstadt, Germany — 7RIKEN, APL, Japan

The BASE collaboration aims for a ppb measurement of the antiproton magnetic moment by using the so-called double Penning-trap technique. Key components for this measurement are superconducting single-particle image-current detection systems for the determination of the antiproton's motional eigenfrequencies. BASE focused on improving the state-of-the-art detection systems in order to achieve a better signal-to-noise ratio for the axial detection systems and shorter resistive cooling time constants for the cyclotron detectors. Benefits are a higher spin-state detection fidelity, shorter measurement times, faster cooling cycles and lower effective particle temperatures.

The talk gives an overview on the design and characterization of our recenty developed detection systems. Compared to previously used detectors, a factor of five higher signal-to-noise ratio was achieved and the cyclotron cooling times were significantly reduced.

100% | Mobil-Ansicht | English Version | Kontakt/Impressum/Datenschutz
DPG-Physik > DPG-Verhandlungen > 2014 > Berlin